# LRMS — Sensor Station (LRMS-0721DC) **Module ID**: `60ca42adad69dac1558f7c64` **Serial**: `7400040721DC0001` **Type**: `lr-ms` **Role**: Pure sensor station — no outputs, no programs --- ## Inputs | Input ID | Name | Type | Unit | Interval | Notes | |---|---|---|---|---|---| | `60ca42adad69dac1558f7c66` | Plumbago | 12 (soil moisture) | % | 60 min | Named sensor | | `60ca42adad69dac1558f7c67` | Pelouse | 12 (soil moisture) | % | 60 min | Named sensor | | `60ca42adad69dac1558f7c69` | *(unnamed)* | 5 (temperature) | °C | 15 min | Air/soil temp | ### Latest readings (2026-06-04) **Plumbago** (moisture) ``` 19:42 71.19% 18:42 74.06% 17:42 71.63% ← irrigation spike visible 16:42 44.64% 15:42 41.83% ``` **Pelouse** (moisture) ``` 19:42 78.25% 18:42 79.63% 17:42 70.81% ← irrigation spike visible 16:42 58.50% 14:42 56.19% ``` **Temperature (unnamed)** ``` 19:42 16.10°C 19:27 16.44°C 18:42 16.66°C 18:12 16.54°C 17:42 16.31°C ``` --- ## Remote state ``` GET /remote/module/state?moduleId=60ca42adad69dac1558f7c64 ``` - Battery: 78% (batteryVoltage field) - Last radio contact: 2026-06-04T19:51:50Z - Relay: `60ca4276ad69dac1558f7c61` (LRMB10) - `relayIsLongPolling: true` --- ## Sensor data endpoint ``` GET /remote/input/getComputedSensorData ?inputId={inputId} &startDate={iso8601} &endDate={iso8601} &ensurePrevTickForContinuity=true ``` The moisture sensor uses a computed expression to convert raw ADC values to %. Moisture spikes (>10% jump) correspond to irrigation events — useful to infer watering history even without direct output events.